top of page
NEXUS


Why Low Humidity Is Critical for Cleanroom Contamination Control | Cleanroom HVAC Design Dublin, Ireland
Discover why maintaining low relative humidity is critical for reducing microbial growth in pharmaceutical cleanrooms. Learn how cleanroom HVAC design, humidity control and M&E design in Dublin, Ireland work together to improve contamination control, protect products and support GMP compliance.

MTS DNC ENERGY CONSULTANTS LIMITED
4 days ago5 min read


Cross-Contamination in Pharmaceutical Manufacturing: Causes, Risks and Prevention Strategies
Cross-contamination is a major GMP risk in pharmaceutical manufacturing. Learn how HVAC systems, pressure cascades, dust extraction, cleaning procedures and facility design help protect products and patients.

MTS DNC ENERGY CONSULTANTS LIMITED
5 days ago5 min read


Facilities and Buildings: How Poor Design and Maintenance Can Cause Cleanroom Contamination
Buildings and facilities play a critical role in contamination control. Learn how poor design, inadequate maintenance, dust, equipment, raw materials and building materials can introduce viable and non-viable contamination into cleanroom and GMP environments.

MTS DNC ENERGY CONSULTANTS LIMITED
5 days ago5 min read


People – The Largest Source of Cleanroom Contamination | Cleanroom HVAC Design & M&E Design Dublin, Ireland
People are the largest source of contamination in pharmaceutical cleanrooms, contributing approximately 75% of all airborne particles. Learn how human activity affects cleanroom performance and why expert M&E design in Dublin, Ireland, combined with cleanroom HVAC design, is essential for maintaining GMP compliance, protecting product quality and ensuring effective contamination control.

MTS DNC ENERGY CONSULTANTS LIMITED
5 days ago4 min read


The Benefits of Liquid Cooling, Sustainability, Retrofit Challenges and the Future of Data Centres
Liquid cooling is revolutionising data centre efficiency. Learn how improved PUE, lower energy consumption, waste heat recovery and hybrid cooling strategies are helping create more sustainable digital infrastructure.

MTS DNC ENERGY CONSULTANTS LIMITED
5 days ago6 min read


Liquid Cooling Technologies: How Modern Data Centres Remove Heat Efficiently
Discover the three main liquid cooling technologies transforming modern data centres. This guide explains direct-to-chip cooling, immersion cooling, rear-door heat exchangers, CDUs and ASHRAE design standards.

MTS DNC ENERGY CONSULTANTS LIMITED
5 days ago6 min read


Liquid Cooling in Data Centres: Why It Is Replacing Traditional Air Cooling for AI and High-Performance Computing
Artificial intelligence is transforming data centre design. Discover why traditional air cooling is reaching its limits and how liquid cooling is becoming essential for supporting the next generation of high-performance computing.

MTS DNC ENERGY CONSULTANTS LIMITED
5 days ago5 min read


Understanding SLS Load Combinations in Eurocode Design: Characteristic, Frequent and Quasi-Permanent Loads Explained Part 3 of 3
Understanding Serviceability Limit State (SLS) load combinations is essential for Eurocode structural design. This guide explains characteristic, frequent and quasi-permanent loads, ψ₀, ψ₁ and ψ₂ factors, and how engineers assess deflection, vibration, cracking and long-term structural performance.

MTS DNC ENERGY CONSULTANTS LIMITED
7 days ago5 min read


Understanding SLS Load Combinations in Eurocode Design: Characteristic, Frequent and Quasi-Permanent Loads Explained Part 2 of 3
Understanding Serviceability Limit State (SLS) load combinations is essential for Eurocode structural design. This guide explains characteristic, frequent and quasi-permanent loads, ψ₀, ψ₁ and ψ₂ factors, and how engineers assess deflection, vibration, cracking and long-term structural performance.

MTS DNC ENERGY CONSULTANTS LIMITED
7 days ago5 min read


Understanding SLS Load Combinations in Eurocode Design: Characteristic, Frequent and Quasi-Permanent Loads Explained Part 1 of 3
Understanding Serviceability Limit State (SLS) load combinations is essential for Eurocode structural design. This guide explains characteristic, frequent and quasi-permanent loads, ψ₀, ψ₁ and ψ₂ factors, and how engineers assess deflection, vibration, cracking and long-term structural performance.

MTS DNC ENERGY CONSULTANTS LIMITED
7 days ago5 min read


Combined Variable Loads in ULS Design: Understanding Eurocode Load Combinations and ψ Factors
Understanding combined variable loads is essential for Eurocode structural design. Learn how ULS combinations work, why ψ factors are used and how snow and maintenance loads are assessed.

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 126 min read


Why Building Services Engineers Should Be Involved Before Planning Permission Is Submitted
Planning permission is no longer just about architecture. Discover why early Building Services Engineering is becoming essential for modern developments, helping improve energy performance, coordinate plant space, and avoid costly changes later in the project.

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 104 min read


Designing Commercial Heat Pump Systems for Domestic Hot Water: Key Engineering Considerations
Designing a commercial heat pump for domestic hot water is more complex than simply selecting an outdoor unit. Learn how engineers size heat pumps, optimise thermal storage, manage peak demand, and maximise efficiency through intelligent system design.

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 65 min read


Why Choose Professional M&E Design Services for Your Project
When it comes to building or renovating any commercial or residential property, the mechanical and electrical (M&E) systems are crucial. These systems ensure that the building operates efficiently, safely, and comfortably. Choosing professional M&E design services can make a significant difference in the success of your project. This article explores why hiring a professional M&E design company is essential and how it benefits your construction or refurbishment project. The I

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 64 min read


Why Heat Pumps Are More Efficient Than Gas Boilers: Understanding the Vapour Compression Cycle
Heat pumps and gas boilers operate on completely different principles. While boilers are limited to ~90–95% efficiency, heat pumps can deliver 3–5 times more energy than they consume by extracting renewable heat from the environment.

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 54 min read


Why Cold Water Tastes Better: The Science of Dissolved Oxygen and Why Steam Systems Remove It
Cold water tastes fresher because it contains more dissolved oxygen, but in steam systems oxygen becomes a major cause of corrosion. Learn how temperature affects dissolved oxygen and why boiler feedwater is deaerated in modern heating and industrial applications.

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 53 min read


Benefits of Using IESVE and DesignBuilder for Heat Loss Calculations Compared to BER HLI
Advanced thermal modelling tools such as IES VE and DesignBuilder provide detailed heat loss calculations that go beyond the standard BER Heat Loss Indicator (HLI). This article explains how simulation-based design improves accuracy, supports HVAC sizing, and enhances building energy performance compared to traditional BER assessments in Ireland.

MTS DNC ENERGY CONSULTANTS LIMITED
Jul 53 min read


Condensing vs Desiccant Dehumidifiers: Which Saves More Energy
This article compares condensing and desiccant dehumidifiers, explaining how each technology works and which is more energy efficient. It covers key differences in performance, applications, and running costs for residential, commercial, and industrial use.

MTS DNC ENERGY CONSULTANTS LIMITED
Mar 293 min read


TT Systems Made Simple: Understanding Fault Protection
TT Electrical Systems: RCDs, Fault-Loop Impedance & Safe Installations In TT electrical systems, safety hinges on how quickly faults are disconnected. Whether you're an electrician, designer, or homeowner, understanding how RCDs and fault-loop impedance work is essential for safe installations. This guide breaks down the key rules from I.S. 10101:2020+A1:2024, including formulas, examples, and the logic behind the Zₛ tables. What Is a TT System? A TT system connects all expos

MTS DNC ENERGY CONSULTANTS LIMITED
Jan 43 min read


⚡ Understanding Fault‑Loop Impedance (Zs) and Why It Must Be Measured
When you install or upgrade a fuse, MCB, or RCBO, one of the most important safety checks is ensuring that the circuit’s fault‑loop impedance (Zs) is low enough for the protective device to disconnect quickly during a fault. This is a core requirement in I.S. 10101 and BS 7671, and it’s essential for preventing electric shock and fire. To help with this, the wiring rules include a table that lists the maximum permitted Zs values for different fuses and circuit breakers at 2

MTS DNC ENERGY CONSULTANTS LIMITED
Jan 33 min read
105 COMERFORDS CROSS
PORTMARNOCK, DUBLIN 13
IRELAND
Tel: 089 603 3521
bottom of page